COLTRIMS Assemblies
No.
Product
Description
Image
502
COLTRIMS80 Spectrometer
Electron/ion twin time-of-flight imaging spectrometer in combination with DLD40, DLD80 or HEX75 detectors. Lengths adjustable, requires vacuum chamber with min. 250 mm inner diameter and detector mounting option FT…/250 or FT…/300 for mounting of the spectrometer and each detector. Incl. spectrometer simulation for a certain application and analysis tools for correlated momentum imaging.
503
COLTRIMS120 Spectrometer
Electron/ion twin time of flight imaging spectrometer in combination with DLD40/80/120 or HEX75/100/120 detectors. Lengths adjustable, requires vacuum chamber with min. 250 mm inner diameter (300 mm recommended) and detector mounting option FT…/250 or FT…/300 for mounting of the spectrometer and each detector. Incl. spectrometer simulation for a certain application and analysis tools for correlated momentum imaging.
512
COLTRIMS251 Main Chamber
Vacuum chamber for spectrometer and detectors (not recommended for HEX100/120), inner diameter > 250 mm, length 700 mm, manufactured from special steel (316 lns), non-magnetic, electro-polished and vacuum-fired for low H2 leakage, optimized for thin jet operation.
513
COLTRIMS301 Main Chamber
Vacuum chamber for spectrometer and detectors, inner diameter 300 mm, length 700 mm, manufactured from special steel (316 lns), non-magnetic, electro-polished and vacuum-fired for low H2 leakage, optimized for thin jet operation. Spectrometer can optionally be fixed onto the chamber for horizontal/vertical mounting.
514
COLTRIMS302 Main Chamber
Vacuum chamber for spectrometer and detectors, inner diameter 300 mm, length 700 mm, manufactured from special steel (316 lns), non-magnetic, electro-polished and vacuum-fired for low H2 leakage with provision of mounting a skimmer or aperture (both included) close to a spectrometer on an inverted (nested) port (about 150 mm negative port length). Spectrometer can optionally be fixed onto the chamber for horizontal/vertical mounting. Special pump port for an intermediate jet pumping stage. Optimized for (two-stage) dense- jet operation.
Supersonic Jet Source
CF200-chamber with X/Y steerable gas jet source (30 micron nozzle) and skimmer. Inclusive ports with manual steering rods and gas inlet through special ultra-clean gas line with filter units (2) and high purity valves (4) rated to a pressure of 30 bars. Incl. Dewar vessel for filter cooling with liquid nitrogen.
521
JS1
for thin jet operation in combination with ES1.
522
JS2
for dense jet operation on COLTRIMS302 Main Chamber or thin jet operation in combination with ES2.
Jet elongation stage for thin-jet operation
Intermediate vacuum pipe system with aperture for differential pumping and individually adjustable 4 jaw slit system. Default distance between jet source and target region 1 m, can be modified between minimum distance (see below) and any distance > 1 m by inserting tube elongations (standard vacuum tubes with CF fittings, not included).
531
ES1
for JS1, minimum jet source – target distance 0.7 m
532
ES2
for JS2, in combination with COLTRIMS302 Main Chamber, minimum jet source – target distance 0.5 m
Jet Dump
jet dump for catching the gas jet inflow behind the target region:
541
JD1
single stage, for thin and intermediate-density jets.
542
JD2
double stage, for dense jets.
560
Mounting Frame
for main chamber with jet source.
570
Vacuum System
set of pumps and ion gauges with controllers and mass spectrometer.
575
Auxiliary vacuum equipment
Heating tapes with power regulators (up to 1500 W) and baking accessories, primary gas jet set with spares, nuts and bolts for mounting all flanges and pumps, blank flanges and CF crosses.
580
Helmholtz coil smart set
Provisions for winding an up to 1 km long 3 mm Kapton-shielded Cu wire (not included) around a support into a Helmholtz arrangement, 1000 W magnet power supply and connectors for Cu wire.
590
Steibulator5D
Manipulator for manually adjusting position (3 dimensions ± 10 mm) and tilt (2 directions ± 10 deg) of small light-weight items, e. g. solid state targets or focusing mirrors (standard customization is for 1″ mirrors with 75 mm focal length), non-magnetic and UHV compatible (bakeable to 150 °C) on CF100 (ICF153) flange. The specimen support is insulated for biasing.
357
FT12-TP/250C
12-pin-ceramics UHV feedthrough and HF signal decoupler with internal HVZ circuit on CF35 (ICF70) norm with UHV cables for delay-line detector (DLD) fitted to customer needs, rated up to 4 kV DC. With mounting kit for DLD40/80/120 for direct mounting via spectrometer rails or directly on CF250-CF35³ adapter flange (ICF253-ICF70³) with two spare ports.
…/300C: …mounting on CF300-CF35³ adapter flange (ICF355-ICF70³), with two spare ports.
One HVT for any two units of 357 or 358 is included (as required for a complete COLTRIMS251/301/302 system).
358
FT16-TP/250C
12+4-pin-ceramics UHV feedthroughs and HF signal decoupler on CF35 (ICF70) norm (2 flanges) with UHV cables for hexanode delay-line detector fitted to customer needs, rated up to 4 kV DC. Includes FT12-TPhex, 3 HFSD plus 1 HFST signal decoupler/terminator and HVZ. With mounting via spectrometer rails or directly on CF250-CF35³ adapter flange (ICF305-ICF70³), with one spare port.
…/300C: …mounting on CF300-CF35³ adapter flange (ICF355-ICF70³)
One HVT for any two units of 357 or 358 is included (as required for a complete COLTRIMS251/301/302 system).