RoentDek PRODUCT LIST
COLTRIMS assemblies |
|
|
|
|
|
Product number
|
Product
Description |
|
|
502 |
COLTRIMS80 Spectrometer: Electron/ion twin time-of-flight imaging spectrometer in combination with DLD40, DLD80 or HEX75 detectors. Lengths adjustable, requires vacuum chamber with min. 250 mm inner diameter and detector mounting option FT…/250 or FT…/300 for mounting of the spectrometer and each detector. Incl. spectrometer simulation for a certain application and analysis tools for correlated momentum imaging. |
|
|
|
|
|
503 |
COLTRIMS120 Spectrometer: Electron/ion twin time of flight imaging spectrometer in combination with DLD40 / 80 / 120 or HEX75 / 100 / 120 detectors. Lengths adjustable, requires vacuum chamber with min. 250 mm inner diameter (300 mm recommended) and detector mounting option FT…/250 or FT…/300 for mounting of the spectrometer and each detector. Incl. spectrometer simulation for a certain application and analysis tools for correlated momentum imaging. |
|
|
|
|
512 |
COLTRIMS251 Main Chamber: Vacuum chamber for spectrometer and detectors (not recommended for Hex100/120), inner diameter >250 mm, length 700 mm, manufactured from special steel (316lns), non-magnetic, electro-polished and vacuum-fired for low H2-leakage, optimized for thin jet operation |
|
|
|
|
513 |
COLTRIMS301 Main Chamber: Vacuum chamber for spectrometer and detectors, inner diameter 300 mm, length 700 mm, manufactured from special steel (316lns), non-magnetic, electro-polished and vacuum-fired for low H2-leakage, optimized for thin jet operation. Spectrometer can optionally be fixed onto the chamber for horizontal/vertical mounting. |
|
|
|
|
514
|
COLTRIMS302 Main Chamber: Vacuum chamber for spectrometer and detectors, inner diameter 300 mm, length 700 mm, manufactured from special steel (316lns), non-magnetic, electro-polished and vacuum-fired for low H2-leakage with provision of mounting a skimmer or aperture (both included) close to a spectrometer on an inverted (nested) port (about 150mm negative port length). Spectrometer can optionally be fixed onto the chamber for horizontal/vertical mounting. Special pump port for an intermediate jet pumping stage. Optimized for (two-stage) dense- jet operation |
|
|
|
|
|
|
Super-Sonic Jet Source: CF200-chamber with X/Y steerable gas jet source (30 micron nozzle) and skimmer. Inclusive ports with manual steering rods and gas inlet through special ultra-clean gas line with filter units (2) and high purity valves (4) rated to a pressure of 30 bars. Incl. Dewar vessel for filter cooling with liquid nitrogen. |
|
|
|
|
521 |
JS1: for thin jet operation in combination with ES1. |
|
|
|
|
522 |
JS2: for dense jet operation on COLTRIMS302 Main Chamber or thin jet operation in combination with ES2. |
|
|
|
|
|
|
Jet Elongation stage for thin-jet operation: Intermediate vacuum pipe system with aperture for differential pumping and individually adjustable 4 jaw slit system. Default distance between jet source and target region 1 m, can be modified between minimum distance (see below) and any distance > 1 m by inserting tube elongations (standard vacuum tubes with CF fittings,, not included). |
|
|
|
|
531 |
ES1: for JS1, minimum jet source – target distance 0.7 m |
|
|
|
|
532 |
ES2: for JS2, in combination with COLTRIMS302 Main Chamber, minimum jet source – target distance 0.5 m |
|
|
|
|
|
|
Jet Dump: jet dump for catching the gas jet inflow behind the target region: |
|
|
|
|
541 |
JD1: single stage, for thin and intermediate-density jets. |
|
|
|
|
542 |
JD2:double stage, for dense jets. |
|
|
|
|
|
560 |
Mounting Frame: for main chamber with jet source |
|
|
|
|
|
570 |
Vacuum system: set of pumps and ion gauges with controllers and mass spectrometer. |
|
|
|
|
|
|
575 |
Auxiliary vacuum equipment: Heating tapes with power regulators (up to 1500 W) and baking accessories, primary gasket set with spares, nuts&bolts for mounting all flanges and pumps, Blank flanges and CF crosses.
|
|
|
|
|
|
|
580 |
Helmholtz coil smart set: Provisions for winding an up to 1 km long 3mm Kapton-shielded Cu wire (not included) around a support into a Helmholtz arrangement, 1000W magnet power supply and connectors for Cu wire. |
|
|
|
|
|
|
590 |
Steibulator5D: Manipulator for manually adjusting position (3 dimensions ± 10mm) and tilt (2 directions ± 10 deg) of small light-weight items, e. g. solid state targets or focusing mirrors (standard customization is for 1" mirrors with 75mm focal length), non-magnetic and UHV compatible (bakeable to 150 °C) on CF100 (ICF153) flange. The specimen support is insulated for biasing. DESCRIPTION SHEET |
|
|
|
|
|
|
357 |
FT12-TP/250C: 12-pin-ceramics-UHV-feedthrough and HF signal de-coupler with internal HVZ circuit on CF35 (ICF70) norm with UHV-cables for delay line detector (DLD) fitted to customer needs, rated up to 4 kV DC. With mounting kit for DLD 40/80/120 for direct mounting via spectrometer rails or directly on CF250-CF35³ adapter flange (ICF253-ICF70³) with two spare ports.
…/300C: …mounting on CF300-CF35³ adapter flange (ICF355-ICF70³), with two spare ports.
|
|
|
|
|
|
|
358 |
FT16-TP/250C: 12+4-pin-ceramics-UHV-feedthroughs and HF signal de-coupler on CF35 (ICF70) norm (2 flanges) with UHV-cables for Hexanode delay line detector fitted to customer needs, rated up to 4 kV DC. Includes FT12-TPhex, 3 HFSD plus 1 HFST signal decoupler/terminator and HVZ. With mounting via spectrometer rails or directly on CF250-CF35³ adapter flange (ICF305-ICF70³), with one spare port.
…/300C: …mounting on CF300-CF35³ adapter flange (ICF355-ICF70³) |
|
|
|
|
|
One HVT for any two units of 357 or 358 is included (as required for a complete COLTRIMS251/301/302 system). |
|
|
|
|
|
|
Please contact us for any requests at:
|
|